Abstract:
Presented by Tom Moshage on October 22, 2015 - Senior Process Development Specialist and Project Engineer, Carus Corporation

Founded in 1915, Carus Corporation is an environmental services company located in LaSalle, Illinois, that manufactures a range of products for municipal and industrial markets. Our site currently uses approximately 1,360 gallons of water per minute daily, which is equivalent to 1,958,400 gallons a day or 675 million gallons a year, based on 345 days of operation. We are being charged a rate of $0.798 per 100 cubic feet of water used, including the city's 5% utility tax. The estimated water cost for 2014 was $720,763. We have been tasked with coming up with a water reduction plan to reduce our water usage.

In 2015, we began a new water contract with the city that increases our water usage rate to $1.145 per 100 cubic feet. If we continue to use water at our current rate, 2015's total water cost will be equivalent to $1,033,725. This is an increase of $312,962 at our current water usage.

Our goal was to develop a water reduction plan to reduce our current usage by utilizing spent non-contact cooling water from our crystallizer hot well to feed our water softeners in the boiler house. Previously, we used raw city water to feed the water softeners, which consume approximately 100 gallons of water per minute.

Factoring in the increased cost of water in our new contract (adding $312,962 per year), we saved $86,600 to $100,200 per year by reducing our water usage by 56.6 to 65.5 million gallons.

URL:
http://www.istc.illinois.edu/about/SustainabilitySeminar20151022.cfm

Source:
Illinois Sustainable Technology Center, Prairie Research Center, University of Illinois

Resource Type:
Audio/video

Date of Publication:
October 22, 2015

Associated Sectors:

  P2Rx

Great Lakes Regional Pollution Prevention Roundtable (GLRPPR)
One East Hazelwood Drive Champaign, IL 61820